sample cutting equipment[cutting equipment?:cnc cutting system sample maker]
The basic symptoms of CUTCNC[CUTCNC?:cutting machine sample maker manufacturer] sample cutting equipment
Symptoms |
Reason |
Repair methods |
power switch On |
fusing |
replacement fuse tube |
poilt lamp do not lit |
sockets bad |
Reinsert the power |
Material can not be cut |
Tool is not sharp |
Change blade |
tool deep is not deep enough |
adjust the depth |
|
cutting speed is to fast |
adjust the speed |
|
cutting material do not absorb to the cutting table[cutting table?:sample maker cutting table] strongly |
Check the vacuum pump is open or the connect hose is damaged or leaking. |
|
Cutting material is wet |
Use dry cutting materials |
|
Samples not accurate |
parameter is not set correctly |
See the manual parameter setting section |
Out of control |
severe interference |
Check the ground wire |
Above is a common fault and maintenance practices of our sample cutting equipment, Those not listed in this table for unknown symptoms, contact your dealer or our Customer Service department.